Application study of complex control algorithm for regenerative furnace temperature
Lusheng GE
摘要:Altemative switch combustion mode of air and gas is adopted on the two sides of the regenerative furnace, its temperature is in uncontrolled state in the switching process and the switch period is generally 3 ~ 5 min. Thus, the conventional bi-cross limited combustion control method is no longer applicable to the object. This paper makes use of neutral network algorithm to adjust the static operating point. On this basis, fuzzy control strategy is used for the furnace temperature control. The actual application result shows that the control strategy is effective to solve the problem of the combustion control for regenerative furnace.
机标关键词:furnace temperatureregenerative furnacecombustion controlcontrol strategytemperature controlapplication resultcontrol methodmode of
分类号:O1(数学)
论文发表日期:2004-01-01
在线出版日期:2025-08-15(本平台首次上网日期,不代表文献的发表时间)
页数:3( 205-207 )
英文信息展开
控制理论与应用(英文版)

控制理论与应用(英文版)

EI
ISSN:1672-6340
年,卷(期):2004,2(2)
所属栏目:Brief Papers