Value of D-Dimers in patients with acute aortic dissection
Chuncai Xue
Yigang Li
摘要:Objective: To evaluatel the value of D-dimers in patients with acute aortic dissection (AAD). Methods: This study consisted of 16 patients with AAD and 27 non-AAD patients. Serum D-dimets were measured by Sta-Liatest D-DI immunoturbidimetric assay. Results: D-dimer level was higher (P < 0.001) in patients with AAD(7.91 ± 5.52 μg/ml) than that in non- AAD group(1.57±1.24 μg/ml). D-dimer was positive (>0.4 μg/ml) in all patients with AAD and in 10 control group patients (37%). Among patients with acute AAD, D-dimers tended to be higher in Stanford A than in Stanford B (8.67 ± 4.31 μg/ml vs. 3.24±1.27 μg/ml, P <0.01). D-dimer values tended to be higher in more extended disease(3.84 ± 1.65 μg/ml, 8.57 ± 3.58 μg/ml and 11.87 ± 5.69 μg/ml in thoracic aorta, thoracic and abdominal aorta, thoracic and abdominal aorta and iliacal arteries, respectively, P < 0.05 for both 8.57 ± 3.58 and 11.87 ± 5.69 vs. 3.84 ± 1.65 ). Including the control group into the analysis, we found a sensitivity of 100%, a negative predictive value of 100%, and a specificity of 66% and a positive predictive value of 64% for D-dimer in diagnosis of AAD in our patients with suspected AAD. Conclusion: D-dimer was elevated in patients with AAD. A negative D-dimer test result could be useful in excluding AAD.
机标关键词:
分类号:R3(基础医学)
论文发表日期:2007-03-02
在线出版日期:2025-08-15(本平台首次上网日期,不代表文献的发表时间)
页数:3( 86-88 )
英文信息展开
南京医科大学学报(英文版)

南京医科大学学报(英文版)

CSCD
ISSN:1674-8301
年,卷(期):2007,21(2)
所属栏目:Research Paper