3D Finite Element Analysis of a Man Hip Joint Femur under Impact Loads
YU Xue-zhong
GUO Yi-mu
LI Jun
ZHANG Yun-qiu
HE Rong-xin
摘要:The biomechanical characters of the bone fracture of the man femoral hip joint under impact loads are explored. Methods: A biosystem model of the man femoral hip joint by using the GE ( General Electric) lightspeed multi-lay spiral CT is conducted. A 3D finite element model is established by employing the finite element software ANSYS. The FE analysis mainly concentrates on the effects of the impact directions arising from intense movements and the parenchyma on the femoral hip joint on the stress distributions of the proximal femur. Results:The parenchyma on the hip joint has relatively large relaxation effect on the impact loads. Conclusion:Effects of the angle δ of the impact load to the anterior direction and the angle γ of the impact load to the femur shaft on the bone fracture are given;δ has larger effect on the stress and strain distributions than the angle γ, which mainly represents the fracture of the upper femur including the femoral neck fracture when the posterolateral femur is impacted, consistent with the clinical results.
机标关键词:Hip Jointhip jointfinite element modelbone fracturebiomechanical charactersimpact loadfemoral neck fracturerelaxation effect
分类号:R473.6(护理学)