Problem analysis and solutions of the B-ultrasound-guided peripherally inserted central catheter process
Zu-Yan Fan
Tian-Tian Wang
Yun Xiao
Yang-En Zhang
Dong-Hao Wu
Zhi-Huan Lin
Dan-Chun Wu
Jin-Xiang Lin
摘要:Objective: The purpose of this study was to address the issues that occur during the B-ultrasound guided peripherally inserted central catheter (PICC) process and to give a summary of the effective management to these issues accordingly. <br> Methods: The information was collected retrospectively on all of the 1950 PICCs inserted during the 2-year period from July 2013 to July 2015. PICC catheter insertion was performed using the Seldinger approach and was delivered from the basilic vein to the superior vena cava in a B-ultrasound guided manner. Moreover, the point raised during the PICC process would be treated immediately. <br> Results: All of the PICCs were inserted successfully. The problems encountered are shown in the inserted central catheter (PICC) process, such as failures of venipuncture, the problem of inserting guide wire, the catheter was difficult to be delivered etc. <br> Conclusions: The B-ultrasound guided approach enhanced the average success regarding the PICC insertion, particularly for the subset with a poor condition in the elbow superficial vein. Due to the items that emerged in the PICC process, the effective prevention prior to surgery and treatment during the operation would be necessary.
机标关键词:guide wire
论文发表日期:2016-01-01
在线出版日期:2025-08-15(本平台首次上网日期,不代表文献的发表时间)
页数:4( 142-145 )
英文信息展开
护理研究(英文版)

护理研究(英文版)

ISSN:2095-7718
年,卷(期):2016,3(3)